Installation sequence
˄
Installation sequence
Installation sequence
1. First clean the sliding ways and the installation surface on the seat to prevent the entry of foreign objects during installation.  Figure 3 Installation method
2. Apply lube oil with low viscocity onto each installation surface and lock gonio ways a, b, c and each surface using the suggested torque force (figure 3-1)
3. Temporarily lock gonio way d (figure 3-2).
4. Remove the retaining screws from any end and insert the roller retainers into the central position of the gonio way; upon the completion of the above operations, restore the screw to its original position. (figure 3-3)
5. Try moving the sliding way horizontally to its maximal traveling end and adjust the roller retainer to its central position.
6. Install a dial gauge at the side of the sliding way base level.
7. Move the sliding way to the traveling end at any side and slightly lock pre-stressed adjustment screw above the roller retainer. (figure 3-5)
8. Move the sliding way to the traveling end at the other side and slightly lock pre-stressed adjustment screw. (figure 3-6)
9. Move the sliding way to the central position and slightly lock the adjustment screw at the central position (figure 3-7).
10. Repeat operations from (7) to (9) until there is no gap in horizontal direction.  Caution against applying excessive pre-stressed loads.
11. Once there is no gap in the horizontal direction, the dial deflection on the gauge is minimal and stable when the sliding way is moved horizontally; at this time carry out final calibration of the pre-stressed loads by repeating operations from (7) to (9) using the torque force recommended for locking screws.
12. Tighten the gonio way d which is temporarily locked in the sequence for locking pre-stressed adjustment screws. ♦ Torque force recommended for locking screws
unit:N.m
Models values of locking
torque force
M2 0.3
M2.5 0.6
M3 1.3
(stainless steel screws)